User Manual

19
EN
1.2 The power cable enters the station through the central opening on the back plate (Single),
or through the center cavity (Double).
1.3 The power connector terminal is located at the top of the station. Make sure the power
supply cable extends out at least 2.5 feet so as to comfortably reach the terminal block.
Step 2: Installing the mounting options
2a. Mounting the CombiPole
EVBox charging stations can be mounted onto a pole. To do this, EVBox offers two types
of CombiPole:
- Surface mounted (PN# 290305 or PN# 290304)
- Inground (PN# 290150)
BusinessLine Single stations are to be attached to the CombiPole by using the
BusinessLine Adapter Kit (PN# 290165) (image below).
The BusinessLine Double stations can be mounted directly on the CombiPole.
Installing the Adapter Kit onto the CombiPole (BusinessLine Single only)
Using the two M5x40 bolts, attach the adapter to the CombiPole as shown on the
following page.
Partially mount the two M5x16 bolts on the adapter kit.
The two M5x16 bolts will be used to mount the unit onto the adapter kit and as such,
should only be partially screwed in. They are tightened after the unit is mounted.
Surface Mounted:
CombiPole (PN# 290305) can be mounted onto a concrete surface.
CombiPole is mounted with four bolts (not provided) to secure the pole to the concrete.
The base plate measures 8” x 8” with four holes (25/64” diameter) for attachment.
Inground:
CombiPole (PN# 290150) can be mounted in soil or dirt.
Dig a hole approximately 2.5 feet deep and 10 inches wide.
Ensure that the mounting holes for securing the charging station are in the correct
position with respect to the parking space(s) and align the pole (PN# 290150) vertically.
Use well-known best practices to solidify the poles foundation.