Step 1: Running the power supply cable
The maximum power rating for the each connector is 7.4 kW or 32A at 230V AC (single or split
phase). Run a power line from the main circuit board with an appropriately rated circuit breaker.
Use a conduit to run the power line to the charging station. The power line enters the station
via the backplate in the case of a single station and through the center cavity for double stations.
Note: BusinessLine Double stations need two separate power cables.
1.1 Remove the cover(s). They are attached to the underside of the charging station with
two hex bolts. For this, use the Allen key (5mm - metric) provided with the charge station.
When mounting the charging station to a wall, the free working space behind the station
is limited. For these situations we recommend using a 5mm mini-ratchet. See “How to
open the cover(s)” (above) for illustrations.
2. Use the Allen key provided to unscrew
(as shown in the image).
1. Locate the two screws at the bottom of the
unit (four screws for the BusinessLine Double).
3. Open the cover from the bottom as
shown. For BusinessLine Double stations,
lift up on the charging cable to give the
cover proper clearance.
Installation steps