RECYCLING At the end of its service life period the product should be recycled according to the recycling procedures in your region. www.evapolar.com Personal Air Cooler evaCHILL EV-500 ©2020 EVAPOLAR LTD. Third edition. All rights reserved.
CONTENTS Safety regulations Basic principles of work To start the device follow the steps Replacing the cartridge Maintenance: cleaning, storage, transportation Troubleshooting Specifications EEE Waste Legal Information 3 6 7 9 11 13 15 16 16
SAFETY REGULATIONS — When using electrical appliances, basic safety precautions should always be followed, including the listed below: — WARNING! Use this device according to its intended purpose as described in this booklet.
— — — — — Do not touch the power supply or power cord with wet hands. Do not place the device next to a heating electrical equipment and other heat sources, including naked flames. Do not place the device upon or next to any other electronic devices (in case of leakage, there is a danger of a short circuit). Do not use the device while bathing or in the shower. Do not operate the device with a damaged cord or plug, if you noticed it is not working properly, if it has been dropped or damaged.
TO START THE DEVICE FOLLOW THE STEPS FILLING WITH WATER 1. 2. 3. 4. 5. Disconnect the cord, protect the USB-port with the silicone plug. Slide the handle backward and lift it up. The water reservoir opening is located under the handle. Push down the locker and open the upper cover. You will find a funnel inside. Fill the reservoir with pure water (filtered water is strongly recommended). Use the funnel for safer filling.
The temperature of the outgoing air will start decreasing in a few minutes. Enjoy your personal microclimate! Depending on air temperature and humidity, the full reservoir should provide from 3 to 8 hours of uninterrupted cooling. TIP: To extend the the time period before the next refill you need to fill up the reservoir, wait until the cartridge is full of water (max. 10 minutes) and then refill the reservoir once again. 4. 5.
MAINTENANCE: CLEANING, STORAGE, TRANSPORTATION STORAGE DURING LONG PERIODS OF NO USAGE We strongly recommend drying the device totally before cleaning, storage and long distance transportation. To do this, you need to set the device to run on the maximum fan speed for at least 4-5 hours to dry the water out from the internal reservoir section. If you’re not intending to use the device for more than 5 days, we strongly recommend the following: • Dry the device and clean it (as described above).
TROUBLESHOOTING PROBLEM: Cold air does not come out of the device despite the fact the cartridge is wet POSSIBLE CAUSE 1: Humidity level over 70% SOLUTION: Ventilate the room POSSIBLE CAUSE 2: The cartridge has expired SOLUTION: Replace the cartridge PROBLEM: Cold air does not come out of the device and the cartridge seems to be dry despite the fact the water tank is full SOLUTION: Since there can be different reasons for that, please, contact our support team PROBLEM: The device does not work at higher spee
SPECIFICATIONS Input voltage / current 5V/2A Power consumption Cooling power 7.5 W 100 W - 350 W / 340 - 1190 BTU/hr Coverage area (in the direction of the airflow) Volumetric Flow Rate Energy Efficiency Ratio (EER) Water tank capacity Water refill cycle Size Weight (without water) Working conditions Working noise level Package set 15 EEE WASTE Up to 2 m2 (21 ft2) 49.1 cfm 21-37 800 ml (27oz) every 3 - 8 hours 172 x 170 x 170 mm (6.77 x 6.69 x 6.
— — with rated current ≤16A per phase and not subject to conditional connection EN 60335-1:2012/AC:2014/A11:2014 - Household and similar electrical appliances. Safety. Part 1: General requirements EN 60335 -2-40:2003/ A11:2004/ A12:2005/ C1:2006/ A1:2006/ A2:2009/ C2:2010/ A13:2012/ A13/AC:2013 - Household and similar electrical appliances. Safety. Part 2-40: Particular requirements for electrical heat pumps, air-conditioners and dehumidifiers.