To charge with a hand pump:
1) Make sure the gun is unloaded by removing the magazine.
2) Engage the safety into the safe position.
3) Connect the hose to the base of the hand pump.
4) Orient the dust cap at the muzzle end of the reservoir to expose the fill hole.
5) Insert the fill probe into the fill hole until firmly seated. No threading is required,
but sometimes using a slight twisting motion while inserting the probe will help.
6) Make sure the bleed nut on pump is tightened down to prevent air escape.
7) Grasp the pump handles firmly with both hands while standing on the footpads
of the pump. Using steady strokes, work the handles up and down fully to
charge the gun's reservoir. Continue to pump until the reservoir gauge shows a
full charge. Do not exceed a charge of greater than 3000 psi (204 bar on
European gauge).
8) Loosen the pump's bleeder valve to allow the excess air to escape. The fill
probe may now be removed and the dust cap twisted to protect the fill hole
from dirt and dust.
9) The gun is now charged. Note the position of the level indicator on the
reservoir's pressure gauge to familiarize yourself with a typical full charge when
using the hand pump (AR6 pistol has no pressure gauge).