User's Manual
40
Models ALL
Input COMMAND ‘M’
LPT Port
LABEL Label
Output DATA[0] SmartKey model
= '1', FX
= '2', PR
= '3', EP
= '9', SP
= 'A', NET
= 'D', XM
DATA[1] Memory available on the dongle
= '0', 0 bytes
= '1', 64 bytes
= '2', 128 bytes
= '3', 416 bytes
= '4', 896 bytes
= '8', 8192 bytes
STATUS Status
==0 Success
!=0 Error
Table 29 MODEL READING MODE command parameters
9.12.1 Parameter transfer
Parameters to be transferred to execute a MODEL READING operation, with access to the dongle on the LPT1 parallel
port.
LPT
01 00
Port
COMMAND
4D 00
Model Reading (
"M"
)
LABEL
53 4D 41 52 54 4B 45 59
00 00 00 00 00 00 00 00
Label ("SMARTKEY")
Table 30
Exchange of information for the MODEL READING MODE command
If the dongle is found on the indicated port, the dongle model is available on the first byte of the Secure Data field.
9.13 Serial number reading mode
This command reads the SmartKey's SerialNumber. The SerialNumber is a 32-bit number unique for every SmartKey.
The exchange of information is organized like this:
Models ALL
Input COMMAND ‘N’
LPT Port
LABEL Label
Output DATA[0,1,2,3] Serial Number