User`s manual
Alarm Management
The 6 alarm inputs of each NDC are corresponding with the first 6 preset points. When an alarm signal is triggered, the
dome will go to the relevant position at 360
o
/sec. Make sure the first 6 preset points are set to desired alarm areas.
Alarm input can be set to NC (normally close) or NO (normally open) depends on alarm detector.
Relationship Between Alarm Inputs and First 6 Presets
z Alarm Input 1 will send the dome to Preset Point 1
z Alarm Input 2 will send the dome to Preset Point 2
z Alarm Input 3 will send the dome to Preset Point 3
z Alarm Input 4 will send the dome to Preset Point 4
z Alarm Input 5 will send the dome to Preset Point 5
z Alarm Input 6 will send the dome to Preset Point 6
Alarm Response Mode
The NDC alarm response can be set to Lock or Release mode.
Lock: dome remains at last alarmed preset point
Release: dome moves between alarmed points then reverts to prior status, such as auto pan.
z Lock Mode
When an alarm is triggered, the dome will go to the relevant position at 360
o
/sec and the keyboard will audio
alert the user until it is canceled manually.
To manually cancel the alarm trigger: Push ALARM RESET key.
If more than one alarm is triggered, the NDC will lock on the last alarm-triggered position.
z Release Mode
Under Auto Pan Condition
When an alarm is triggered under Auto Pan, the NDC will go to the relevant position at 360
o
/sec. After 60
seconds the alarm will be canceled automatically and back to Auto Pan mode. If more than one alarm is
triggered, the NDC will moves between alarmed points every 5 seconds and back to Auto Pan mode after
- 111 -