This jumper is used to disconnect the backup battery to prevent it from draining.
JP2 Description
Battery connected
Battery disconnected (default)
JP3 – LCD logic supply selection
Connector: 3-way, 2.54mm (0.1") single row through-hole header
Pin Signal name
1 +5V
2 LCD Logic Supply
3 +3V3
This jumper selects the supply voltage for the LCD logic supply.
JP3 Description
Supply LCD Logic with 5V
Supply LCD Logic with 3.3V (Default)
If the LCD requires a 5V supply, please refer to the
LCD datasheet to ensure that the display is
compatible with 3.3V logic.