6 Product overview ReliaGATE 10-12 User manual Rev. 2-1
Specifications Description according to -XY versions
-61 -62 -63 -64 -65/ -65G -66/ -66G -67/ -67G
Power Input Nominal: 12 or 24 VDC; Range: 9 to 30 VDC with transient protection
Consumption 2 W idle; 15 W maximum
Environment Operating
Temperature
-40 to +70°C
(1)
Storage
Temperature
-40 to +85 °C
Relative
Humidity
5 to 95% (non-condensing) at +40°C
Certifications Regulatory FCC,
ISED,
CE
FCC,
ISED
CE FCC,
ISED
CE JATE,
TELEC
Safety EN 62368, UL 60950
(2)
Environmental RoHS3; REACH
Wi-Fi/BT
Radio
No FCC,
ISED,
CE
FCC,
ISED
CE FCC,
ISED
CE JATE,
TELEC
Cellular
Radio
No No FCC, ISED,
PTCRB
(AT&T,
Verizon)
CE FCC, ISED,
PTCRB
(AT&T,
Verizon)
CE JATE,
TELEC
Ingress IP40
MTBF > 375.000 h (prediction method: IEC 62380 @ 25°C GF)
Mechanical Dimensions 139 (L) x 115 (W) x 46 (H); mm - Antennas Connectors and Mounting Bracket included
Weight 210 g (without DIN Rail Mounting Clip/Bracket)
Enclosure Material: ABS- Color: Aluminium
Operating System
Yocto Linux** + ESF
** Factory Option: Secure Boot - Yocto Linux
(1)
Software ensures that the system doesn't exceed the maximum operating temperature (+70 °C)
(2)
Factory Option
26 / 118