If your customer has been using a local printer and has lost the use of it because of DVACS
(tm)
operation, then you may install a Model 3302R3 port splitter. This device splits the panel
serial-communications port into two separate ports. One port on the Model 3302R3 is then
reconnected to the F1F2 subset and the other port would be connected to the local serial-input
printer. Real-time events from the panel and the printing of reports will now be logged on the
printer.
The following section has been added to explain the library messages which are sent to the
Central/Monitoring station automation software. If the station operator notifies you that a certain
‘strange code’ has been received, look it up in this section for an explanation.
LIBRARY MESSAGES
The following table lists the zones and messages for 3GS, Aplex, Midiplex, Directplex, and
Transponders.
HEX DECIMAL LIBRARY MESSAGE CONTEXT U=User Selection, S=Status
CODE CODE Alert, - = Not Transmitted
21 33 MODE 6 U
22 34 MODE 7 U
23 35 MODE 8 U
24 36 MODE 9 U
25 37 AREA SETUP U
26 38 CARD INFO U
27 39 FORCE CALL U
28 40 SET UP DM 1200 U
29 41 NODE CONFIGURE U
2A 42 OUTPUT TEST U
2B 43 CLEAR SOAKS U
2C 44 SOAK MODE U
2D 45 COMMAND MODE U
2E 46 FAULT ON EXIT S
2F 47 SETUP CARDS U
30 48 PAGER TEST U
31 49 NODE/CABINET TAMPER S
32 50 NODE LOST S
33 51 NODE PORT 1 OFFLINE S
34 52 NODE PORT 2 OFFLINE S
35 53 NODE RESET S
36 54 MEMORY ERROR S
37 55 POWER/FUSE FAIL S
38 56 DUPLICATE SERIAL # U
39 57 NETWORK RECONFIGURED U
3A 58 DATA CHANGED U
3B 59 CABLE FAULT S
3C 60 HOLIDAY S
3D 61 ACCESS MSG S