Installation guide
74
NOTES CONCERNING THE MODEL 1431/32 AUTO-DIAL MODEMS cont.
commands, consult any commercial auto-dial modem manual. Press the RETURN/ENTER key
to proceed.
The display will now show ENTER TEL. NO. 1 followed in a moment by a blank screen. Enter
the telephone number of the auto-dial modem at the remote location. A 2-second pause between
numbers can be included by entering a comma (shift shift PART ARM 1) (e.g., 9,4167548992).
Press the RETURN/ENTER key to proceed.
The display will now show ENTER TEL. NO. 2. If an alternative location is available for use
when no connection can be made with the first number, then enter a telephone number;
otherwise, either leave this entry blank or re-enter the first number. Press the RETURN/ENTER
key to proceed.
If access mode 2 (the dial-back option) was chosen above, the display will now show ENTER
DIAL-BACK NUM followed in a moment by a blank screen. Enter a telephone number that the
panel can call to allow linking to the PANELMAN program. Press the RETURN/ENTER key to
proceed.
The display will now show TRANSMIT NAME YES or TRANSMIT NAME NO. Press the
YES key to select yes, the NO key to select no, or the RETURN/ENTER key to maintain the
current setting. If no is selected, the display may show DATA BITS =7 ? or DATA BITS =8 ?
(proceed to the next paragraph). If the panel is in dial mode 1 and yes is selected, the name and
address of the installation will be transmitted to a remote printer every time that data is sent. This
allows any EUROPLEX 3000 series control panel to access a common remote printer by
ensuring that the data from each panel can be uniquely identified on the printout. When yes is
selected, the display will show ENTER NAME/ADDRESS for a moment and then the current
name and address, if any. This can be entered or edited as required. Press the RETURN/ENTER
key to proceed.
The display may now show DATA BITS =7 ? or DATA BITS =8 ?. When the panel is sending
or receiving data, it will transmit or listen for a 7-bit or 8-bit data word. In some applications, the
word length must be changed. If the panel is in dial mode 1, the word length of the remote
printer may be already set as seven bits long. When the panel is in dial mode 3, the word length
must be eight bits long for either remote or local use with PANELMAN software and for remote
communication with the Model 1430 auto-answer modem/polling multiplexer interface. Press
the RETURN/ ENTER key to accept the value shown or press the NO key to change to the other
value. If the NO key is pressed to select an 8-bit word, the display will show PARITY =EVEN.
As above, if the dial mode is 3, no parity is required for remote use with PANELMAN software
or with the Model 1430 modem/multiplexer interface. Press the YES key to accept even parity or
press the NO key to select no parity. If the NO key is pressed, the display will show PARITY
=NONE for a moment (if the NO key was pressed previously to change an 8-bit word