Installation guide
62
listed below. The AUDIBLE SILENCE 1 (-) key may be used to return to a previous option. To
exit from this option, press the NO key whenever the display shows ENTER USER NO. #. The
display will now show QUIT ? and you may press the YES key to exit or any other key to
return to the sub-menu.
The following is the Master user’s list of all possible options:
DISARM CLEAR DISPLAY 9 KEY
AUDIBLE SILENCE 1 SYSTEM LOG SET IDS/OPTIONS
AUDIBLE SILENCE 2 SINGLE-ZONE SHUNT
FULL ARM SET DATE/TIME
NAMES - To select NAMES, press the HELP key. The display will show ENTER USER
NO. 1. If user number 1 is to be chosen, press the RETURN key. If a user other than number 1
is to be chosen, enter his or her number and then press the RETURN key. Now you may enter
the user’s name. (See page 4 for information on entering letters of the alphabet.)
ASSIGN ZONES/VARIABLES (D key): There are nine instant-acting area zone types in the
APLEX 3100E8 8-area control panel, one for each of the individual areas and one for the
common area. There are also five exit/entry zone types and two follower zone types. In addition,
there are a number of other zone types that can be used for supervisory functions: technical, gate,
pressure, etc. (Zone types are explained in detail on pages 30 to 34.) To select this function, enter
the Service user code and then press the D key (shift AUDIBLE SILENCE 1). The display will
show the sub-menu DESCS---TYPES--VARS.
DESCS - Press the FULL DISARM key to select DESCS. The panel will display ENTER
ZONE NO. 1. If this is the desired zone, then press the RETURN key; otherwise, enter the
number of the required zone and then press the RETURN key. The display will then show a
flashing cursor, /\, in the farthest-left position. Enter the zone number, followed by a zone
description up to 18 characters long. (See page 4 for instructions on the use of the keyboard.)
When the entry is complete, make sure that the cursor is at normal shift (up) and then press the
RETURN key. The panel will display ENTER ZONE NO. # for the next zone in the sequence.
Proceed as described above. To exit, press the NO key whenever the display shows ENTER
ZONE NO. #. The QUIT ? message will appear and you may press the YES key to exit or any
other key to return to the sub-menu.
TYPES - Press the AUDIBLE SILENCE 2 key to select TYPES and then assign the appropriate
zone type (see pages 30 to 34) to the relevant zone numbers. When all the zone types have been
assigned, press the NO key to exit from this selection. Then, when the display shows QUIT ?,
press the NO key to return to the flashing sub-menu.
QUICK PROGRAMMING GUIDE cont.
VARS - Press the HELP key to select VARS to set the entry/exit delay times for areas 1 through