Installation guide
61
DISARM). The panel will display a flashing sub-menu: IDS--OPTIONS-NAMES.
IDS (IDENTIFICATION CODES) - To select or change identification codes (IDS), press the
FULL DISARM key. The panel will display ENTER USER NO. 1. The Service user is always
user number 1 and the Master user is always user number 2. General users are user numbers 3
through 250. Enter the desired user number and then press the RETURN key. The next message
displayed will be ENTER CODE _ _ _ _ _. User codes can have four or five digits (see page
L 36). If you are using four-digit codes, enter any numeric code from 1000 up to 9999. (Note that,
unlike in the previous software, numeric codes 1 to 0999 are not allowed. This is because the
new Duress Alarm feature described on page 67 uses a lead 0 numbering scheme.) If you are
using five-digit codes, enter any numeric code from 1000 to 32767. After a code is assigned, you
must press the RETURN key to advance to the next user number. If this user requires a code,
then press the RETURN key and follow the procedure described above; if not, then enter the
required user number and proceed as above. To exit, press the NO key when the display shows
ENTER USER NO. #. The QUIT ? message will appear and you may press the YES key to
exit or any other key to return to the sub-menu.
L REMOVING A USER CODE: Select IDs as above, enter the user number in question, press
the RETURN key, enter a single * (AUDIBLE SILENCE 2 on panel, PART ARM 2 on keypad)
for the code, and then press the RETURN key again. This will delete the old code. Press the NO
key to quit and the YES key to exit.
RESETTING USER 1 AND 2 IDS: If through the course of staff changes, etc., the Service
user’s code or the Master user’s code has been lost, then these two user codes only may be reset
to the factory default value (i.e., Service user 1 will again have code 1010 and Master user 2 will
again have code 1020). New codes may then be assigned. All other user codes will remain
unchanged!
To perform this reset procedure, open the panel door and press the CPU reset button to the left of
the display. Quickly close the door and press the AUDIBLE SILENCE 2 key when the display
shows A100 8A250U 29MAY00. The piezo-sounder will beep and the display will show
RESET USER 1&2 IDS ?. Press the YES key to reset the Service user's code to 1010 and the
Master user's code to 1020 or the NO key to leave them unchanged.
OPTIONS - To select OPTIONS, press the AUDIBLE SILENCE 2 key. The panel will display
ENTER USER NO. 1. Enter the number of the user to whom you wish to assign the options
and press the RETURN key. The panel will now display FULL DISARM NO. If you do not
wish to allow this general user to fully disarm the panel, press the RETURN key. The flashing
NO will remain and the next option will follow. If this option is to be allowed, then press the
YES key. This changes the NO to a YES on the panel to confirm your choice. The next option
will then appear, along with NO. This procedure must be repeated for this user for all options
QUICK PROGRAMMING GUIDE cont.