LOG DATA TYPE SELECT
1 - Zone activations 1
2 - Status changes 2
3 - User actions 4
4 - Output switching 8
5 - Variable values 16
6 - Single-byte variable 32
7 - User-defined message format 64
8 - Date change (never reported) N/A
9 - Not used 256
10 - Zone shunting 512
11 - Zone unshunting 1024
12 - Zone disabling 2048
13-15 - Not used 4096
8191
For example: If only zone activations are to be reported, set the log filter to 1. If zone activations
and user actions are required, set the log filter to 5 (1 + 4). The default value is all choices
(8191). Enter the new value or press the RETURN key to proceed.
The display will now show DIAL MODE 0. Press the RETURN key to leave the value at 0 for
logging printer only and DVACS
(tm)
operation and the display will show DATA BITS =8 ?; in
this case, proceed to page 58 where this display is shown in bold type; otherwise, an autodial
modem may be connected to the APLEX control panel to allow remote communications over the
switched telephone network. A number of choices allow data to be sent to a remote printer or
computer. If an autodial modem is connected, set DIAL MODE 0 to 1 or 3. Enter the appropriate
value as determined from the following chart and press the RETURN key to proceed.
0 - No auto-dial modem connected.
1 - A logging printer is connected to an auto-dial modem at the remote location. When any
event is logged by the panel, but not filtered by the log filter, the remote location will be dialled
immediately and any logged data will be sent to the remote printer. When all the data is sent, the
panel will instruct the auto-dial modem to hang up.
2 - Allows PANELMAN to dial into the panel to perform upload/download functions.
3 - A personal computer with PANELMAN software or a EUROPLEX Model 1430 auto-
answer modem/polling multiplexer interface. The following options appear for dial modes 1, 2,
and 3 but they are relevant for dial mode 3 only. The display will show ACCESS MODE 0.
Leave this value unchanged if unrestricted access is to be allowed when dialling remotely into
the panel using the PANELMAN program. If you wish to restrict access by means of a
password,