Installation guide

48
RETURN key; otherwise, enter the number of the required zone and then press the RETURN
key. The display will then show a flashing cursor, /\, in the farthest-left position. Enter the zone
number, followed by a zone description up to 18 characters long. (See page 4 for instructions on
the use of the keyboard.) When the entry is complete, make sure that the cursor is at normal shift
(up) and then press the RETURN key. The panel will display ENTER ZONE NO. # for the next
zone in the sequence. Proceed as described above. To exit, press the NO key whenever the
display shows ENTER ZONE NO. #. The QUIT ? message will appear and you may press the
YES key to exit or any other key to return to the sub-menu.
ZONE TYPES - To select ZONE TYPES, press the AUDIBLE SILENCE 2 key when the
flashing sub-menu is displayed. The panel will then display SET FROM 1. If the required
zone is number 1, then press the RETURN key; otherwise, enter the number of the required zone
and press the RETURN key. The panel will display SET TO #. If a range of zones is required,
enter the upper limit and press the RETURN key; otherwise, just press the RETURN key. The
panel will respond with AREA-1 ?. In the same manner as with the OPTIONS option (see page
46), select the appropriate zone type to be allocated to this zone or group of zones. To exit, press
the NO key whenever the display shows SET FROM 1. The QUIT ? message will appear and
you may press the YES key to exit or any other key to return to the sub-menu.
SYSTEM VARIABLES - To amend system variables, press the HELP key when the flashing
sub-menu is displayed. The system variables will now be presented. In response, enter time
values in seconds (e.g., 10 minutes = 600 seconds) or select a condition specified by a numeric
entry. Note: The time entries can range from 1 to 9999 seconds and 0 seconds means infinite
time (forever). If no entry is required, press the RETURN key to advance to the next item. Use
the AUDIBLE SILENCE 1 (-) key to return to the previous entry.
FULL ARM EX TIME 30: This is the delay time in seconds that a user is allowed to exit the
premises via any area exit door from the moment the system is placed in FULL ARM mode.
C-EXIT TIME 30: If a C-EXIT (Common-EXIT) zone type has been assigned, this variable
sets the amount of entry delay time allowed for entry into the common area.
EXIT-1 TIME 30: If an EXIT-1 zone type has been assigned, this variable sets the amount of
exit and entry delay time allowed for exit from and entry into area 1.
EXIT-2 TIME 30: If an EXIT-2 zone type has been assigned, this variable sets the amount of
exit and entry delay time allowed for exit from and entry into area 2.
EXIT-3 TIME 30: If an EXIT-3 zone type has been assigned, this variable sets the amount of
PROGRAMMING THE PANEL cont.
exit and entry delay time allowed for exit from and entry into area 3.