Installation guide

45
1. In the SINGLE-ZONE MONITOR option, if a 2K2-ohm resistor is connected between
terminals 6 and 7, the display will show AREA-1 5 CLOSED [28].
2. If the circuit is opened between terminals 6 and 7, the panel will show
AREA-1 5 DISCON [89].
3. If a short circuit is placed across terminals 6 and 7, the panel will show
AREA-1 5 SHORT [3].
4. If two resistors in series are connected to terminals 6 and 7, the panel will show
AREA-1 5 OPEN [42].
The number in square brackets represents the analogue value of the voltage coming from the
LEM zone input and should be within +2 of this value. By examining different inputs, you will
be able to determine the analogue values for all zones and these can be printed or recorded for
future reference when trouble-shooting faulty zones. A table of acceptable analogue values
follows:
INPUT COND. MIN. MAX. TYP.
SHORT 0 21 3
CLOSED 22 36 28
OPEN 37 55 42
DISCON 56 90 85
These readings will remain near the typical values unless the resistance of the LEM trunk
increases due to excessive length (around 1500 metres) or until the limit of cable capacitance
is reached, at which point they will increase as extra cable is added. The system assumes a
nominal cable capacity of 50 pf/m to allow 2-km maximum length.
During initialization, zones with marginal responses will also be displayed. Zones with values
that are outside of the min./max. range will be individually displayed. (See LEM-LINE
INITIALIZATION on page 35 for further information.)
SET IDS/OPTIONS (C key): Both the Service user, user number 1, and the Master user, user
number 2, can select this function to set identification codes for the 248 general users. These two
users can also assign functions and modes to other users but each will be presented with a
different list of functions and modes to choose from. General users, if authorized, can then re-
assign their functions and modes to others. At any point, should a general user attempt to enter a
function or mode other than that permitted in his or her list, the display will show ** INVALID
ENTRY **. Enter your user code and then press the C key (shift FULL DISARM). The panel
will display a flashing sub-menu: IDS--OPTIONS-NAMES.
PROGRAMMING THE PANEL cont.