Installation guide

42
PROGRAMMING THE PANEL cont.
YES key to make a hard-copy record of the system log. While the printing is in progress, the
display will show PRINTING SYSTEM LOG. If a printed copy is not required, press any
other key. The display will briefly show SYSTEM LOG and the log will then be scrolled on the
display. To abort the system log at any time, press the NO key. The format of the displayed
output is as follows: Starting with the last event and working back in time, the panel will show
three messages for each alarm entry:
Message 1 is DATE**TIME
Message 2 is ZONE NUMBER or USER NUMBER
Message 3 is ZONE DESCRIPTION or ACTION TAKEN BY USER
The date and time are separated by ** to distinguish an historical log display from the normal
DISARM mode display. The content of the second and third messages will depend on whether it
was a user action (e.g., SET DATE/TIME), in which case the user number will be the second
message and action taken will be the third message, or a zone changing state, in which case the
zone number will be the second message and the zone description will be the third message. The
alarm log is capable of storing 600 of these three-part entries. While the log is being displayed,
you may press the RETURN key to advance each line entry on the display. You may also press
the FULL DISARM (+) key to move just the time entry back in time more quickly (i.e., to the
older log entries) and then you may press the AUDIBLE SILENCE 1 (-) key to advance just the
time entry forward in time more quickly (i.e., to rewind the log to the most recent entry). When
you stop pressing these keys, the log will again continue its slow scroll back in time. This will
allow you to easily review any display. When all entries have been displayed, the word
FINISHED will appear and the panel will return to date and time. Press the NO key at any time
to abort the system log.
SINGLE-ZONE SHUNT (NO key): This function provides a simple method of shunting when
only a single zone is to be shunted or the total number of zones to be shunted is quite small.
Enter your user code and then press the NO key. The display will show SHUNT ZONE 0. Enter
the number of the zone that is to be shunted and press the RETURN key. The display will then
show the description of the zone (e.g.,
t3. MANAGER'S OFFICE), if one exists, or, if no
description exists, the display will show the zone type and zone number (e.g.,
tAREA-1 3).
Having a zone description allows the user to see exactly which zone has been shunted. The
flashing t to the left of the description indicates that the zone is currently shunted. If an
incorrect zone number has been entered, that zone can be un-shunted by pressing the YES key.
(Pressing the YES key, in fact, toggles the shunt on and off. As the YES key is pressed, the
flashing
t will come and go indicating whether a zone is shunted or not.) The FULL DISARM
(+) key can be used to select higher zone numbers and the AUDIBLE SILENCE 1 (-) key can be
used to select lower zone numbers. By using the FULL DISARM (+), AUDIBLE SILENCE 1
(-), and YES keys, you can quickly step through a range of zones and examine or change their
status. If the zone displayed is the one to be shunted, then press the RETURN key and the panel
will exit from