Installation guide

40
Some functions or modes are self-completing (i.e., they exit automatically). Others will require
further action. For the SET DATE/TIME and SET TIME COMMANDS functions, enter a military
(24-hour) time and press the RETURN key to exit. Other functions will display a flashing
sub-menu. To select from these sub-menus, follow the guidelines on the keyboard leading to the
FULL DISARM, AUDIBLE SILENCE 2 (previously PART ARM 2), or HELP keys and press the
one that is appropriate. For example, in SERVICE MODE mode, a sub-menu of three choices will
appear. These will be REPORT--TEST-MONITOR. If you wish to choose REPORT, then press
the FULL DISARM key; if TEST, then press the AUDIBLE SILENCE 2 (previously PART
ARM 2) key; and if MONITOR, then press the HELP key. Having made your choice, follow the
instructions that appear on the next display. To exit, press the NO key when there are no further
entries to be made. Then, when the display shows QUIT ?, press the YES key to exit, or any other
key to force a redisplay of the sub-menu.
IMPORTANT!! Do not leave the panel with a sub-menu showing. Anyone could make a selection
and gain access to the premises later. Always complete your selection and exit to date and time.
EXPLANATION OF FUNCTIONS AND MODES
L Note that a four-digit code entry in the four-digit code option or a five-digit code entry in a
five-digit option will be presumed in the following explanation of functions and modes. Should a
four-digit code be entered when the five-digit code option has been chosen, then you must press
the RETURN key to complete the entry.
OPTIONS AVAILABLE (HELP KEY): This function is included to help the user who is not
sure of the system options available. Enter your user code and then press the HELP key. The panel
will display SELECT AN OPTION..., followed by the first option available. The option will
have a ? beside it. If you wish to select this option, then press the YES key. If you do not wish to
select this option, then press the NO key to continue on to the next available option. This
procedure must be repeated until an option is chosen. To exit from this function without choosing
an option, repeatedly press the HELP key until you see CLEAR DISPLAY. Press the YES key.
ACKNOWLEDGE ALARMS (0 key): This function is used to acknowledge receipt of an alarm
condition (e.g., **FIRE ALARM**). Enter your user code and then press the 0 (zero) key. This
action will stop the flashing display, silence the piezo-sounder, and turn off the bells. A tamper or
disconnect condition on any zone will also create an alarm that is logged in the system log. When
this happens, both the zone description and zone state are displayed. This may be acknowledged to
stop the piezo-sounder.
DISARM (FULL DISARM key): This is the normal daytime or open-period operating mode. To
disarm the panel, enter your user code and then press the FULL DISARM key. When the panel is