Installation guide

32
area armed. If all areas are to be armed at the same time using the FULL ARM key, then the exit
time will be that programmed for the Full Arm Ex Time variable (see page 48). When entry is
made into the common area through a C-EXIT zone, the piezo-sounder will beep to remind that
user to disarm his or her individual area. Disarming an individual area will stop the common exit
timer. The amount of entry time allowed is that programmed in the C-Exit variable (see page
48).
FIREDR: This normally closed zone type is used with fire exit doors that should never be
opened when the premises is occupied. Violation of this zone is displayed locally and transmitted
to the central/ monitoring station. While any one or more areas of the system are disarmed, an
open on this zone will operate FIREDR group output C-LEM 14, cause the piezo-sounder to
beep, the event to be logged, and the display to show the flashing alert message *FIRE DOOR
OPENED*, alternating with a flashing zone description. When all areas of the system are armed,
this zone responds as an instant-acting COMMON zone (see above).
PANIC: This normally closed zone type should be used with latching panic buttons to ensure
that activation will be detected. An open at any time will operate CONTINUOUS BELL panel
relay output 7 and output C-LEM 7 and PANIC output C-LEM 9 and cause the piezo-sounder to
beep, the event to be logged, and the display to show the flashing alert message **PANIC
ALARM**, alternating with a flashing zone description. PANIC is an audible HOLDUP zone!
HOLDUP: This normally closed zone type should be used with latching holdup buttons to
L ensure that activation will be detected. An open at any time will operate HOLDUP output
C-LEM 13 and cause the event to be logged but piezo-sounder will not beep. Note: Since the
panel will display a zone description any time a zone is violated, you should program a zone
description that avoids the use of the word HOLDUP; choose some innocuous phrase such as
TEST ZONE X. HOLDUP is a silent PANIC zone!
L TELFLT: This normally closed zone type is used to monitor the relay output of a dialler
telephone line-cut module. An open on this zone will operate TELFLT output C-LEM 15 and
cause the event to be logged. If any one or more areas of the system are disarmed, the piezo-
sounder will beep and the display will show the flashing alert message *TELCO FAULT*,
alternating with a flashing zone description. When the TELFLT zone is restored, output C-LEM
15 will be reset and the event will be logged.
24HOUR: This normally closed zone type is used with foil, fine wire, emergency doors, etc.
When any one or more areas of the system are disarmed, an open on this zone will operate
INTRUSION ALARM panel relay output 1 and output C-LEM 1 and 24HOUR output C-LEM 18,
which may be used for local annunciation (buzzer, lamp, etc.), and cause the event to be logged. If
the Alert & Display variable (see page 49) has been set to one (1) for an attended site, then the
piezo-sounder will beep and the display will show the flashing alert message ** INTRUDER
ALARM **, alternating with a flashing zone description. When all areas of the system are armed
(i.e., the panel is fully armed), this zone responds as an instant-acting COMMON zone (see page
31).