IMPORTANT SAFETY INFORMATION
Read these instructions carefully before installing or trying to operate this Vent Free gas heater.
5. Any safety screen or guard removed for servicing an appliance, must be replaced prior to operating
the heater.
6. Installation and repair should be done by a qualied service person. The heater should be inspected
before use and at least annually by a professional service person. More frequent cleaning may be
required due to extensive lint from carpeting, bedding material, etc. It is imperative that control
compartments, burners and circulating air passageways of the heater be kept clean.
7. To prevent malfunction and/or sooting, an unvented gas heater should be cleaned before use and at
least annually by a professional service person.
8. CARBON MONOXIDE POISONING: Early signs of carbon monoxide poisoning are similar to the u
with headaches, dizziness and/or nausea. If you have these signs, obtain fresh air immediately. Have
the heater serviced as it may not be operating properly.
9. The installation must conform with local codes or, in the absence of local codes, with the National
Fuel Gas Code, ANSI Z223.l/NFPA54.
10. This unit was tested and listed to ANSI Z21.11.2-2011 by OMNI-Test Laboratories.
11. This appliance is approved for installation in the Commonwealth of Massachusetts. The Board of State
Examiners of Plumbers and Gas Fitters has issued approval number G1-0513-436 for this appliance.
12. Do not install this heater in a bathroom or bedroom.
13. Correct installation of the re media, proper location of the heater, and annual cleaning are
necessary to avoid potential problems with sooting. Sooting, resulting from improper installation or
operation, can settle on surfaces outside the replace. See media placement instructions for proper
installation.
14. WARNING: Avoid any drafts that alter burner ame patterns. Do not allow fans to blow directly into
replace. Do not place a blower inside burn area of rebox. Ceiling fans may create drafts that alter
burner ame patterns. Sooting and improper burning will occur.
15. Caution: Candles, incense, oil lamps, etc. produce combustion by-products including soot. Vent
Free heaters will not lter or clean soot produced by these types of products. In addition, the smoke
and/or aromatics (scents) may be reburned in the vent free heater which can produce odors. It is
recommended to minimize the use of candles, incense, etc. while the vent free heater is in operation.