Owner`s manual
APPENDIX TWO
WIRING to a HOME AUTOMATION SWITCH (OPTIONAL)
External control of your H Series replace is an either/or proposition; you control it with either a home
automation switch (not included) or the remote control (included). The home automation system cannot
adjust the ame height; it can only turn on (with a high ame) or o.
When using a home automation system:
1. The jumper across X4 is removed and replaced with a DRY CONTACT CLOSURE (DCC, millivolt-rated, MUST
make clean break) using a Phoenix Contact GMSTB 2,5/ 2-ST-7,62 plug (not included.)
2. The remote control must then be disconnected from the system by pressing the SW1 button (see gure
above) TWICE in succession.
From then on, when the DCC is closed the re goes on to high ame and when the DCC is opened the re
goes o. The ame height cannot be adjusted with the home automation system.
IFC
Control
Module
Power Plug
Gas Valve
Pilot Burner
X4 X5
X1
SW1
Back-up
Battery
Case
DCC
Connects
Here
(see text)