A qualied service agency should conduct an annual inspection and maintenance of your H Series Vent
Free Gas Fireplace to keep it running safely. The following procedures should be performed only by a
qualied service person. The gas supply should be turned o whenever a maintenance procedure is
performed. All parts of the replace that are removed for servicing must be replaced prior to operation.
Cleaning the Media and Burner.
With all parts of the replace at room temperature, carefully remove and clean the re media with a soft
bristled brush.
Lift o the hearth panel and clean the burner surface with a brush and clean the rest of the burner module,
including the pilot burner, with a vacuum cleaner. After lifting o the Hearth Panel, ensure that the Primary
Air Openings (shown in Figure 14, at the end of each Burner Inlet Tube) remains free of dust or debris. These
openings may cleaned with a vacuum cleaner or brush.
Primary Air Openings
Burner Inlet Tubes
Failure to keep the primary air opening of the burner clean may result in sooting
and property damage.