Owner`s manual
H Series Vent Free Gas Fireplace EuropeanHome.com
OPERATING the FIREPLACE
21
BEFORE THE FIRST FIRE
1. Make sure all construction materials have been removed from inside and around the replace.
2. Conrm that the electrical wiring is properly connected.
3. Check the gas supply for leaks.
4. Conrm the proper placement of the burner media.
THE FIRST FIRE
The rst time you light your H Series Vent Free Gas Fireplace an odor may be given o by the unit. This is
normal and is a result of the ‘burn o’ of the lubricants and sealants used when manufacturing the replace.
We recommend that you open the nearby windows for extra ventilation and operate the replace for at least
four hours.
During this rst re, examine the ame for appearance and quality. Examine the burner media for sooting.
The ames should look like those in Figure 15.
Since it is a metal replace, the heat-up and cool-down cycles may produce some noises caused by the
expansion and contraction of these metals. The premium materials and build quality of your H Series Vent
Free Gas Fireplace will keep these sounds to a minimum.
The re media must be installed per these instructions. This heater must use only the re media provided
by European Home. An excess amount of re media may adversely aect the performance of the heater.
WARNING: All previously applied loose material must be removed prior to reapplication.