GAS INSTALLATION
18
Figure 10. Gas Supply Opening On Rear (see text)
INSTALL THE GAS SUPPLY
For the HVF-42-3S, HVF-60-3S and HVF-72-3S models a 2” x 4” opening in the lower left rear is provided for
the gas supply.
The gas supply piping should have a separate gas shuto valve and a capped, 1/8” pipe tapping upstream of
the valve for the purpose of reading pressure. A service shuto valve must be placed within six feet of the
replace gas control valve.
The gas supply line must terminate with a ½” male are tting.
The replace must be isolated from the gas supply system by closing the service valve during any pressure
testing of the gas supply system at test pressures equal to or less than ½ psi (3.5 kPa). Verify the gas pressure
using the upstream 1/8” pipe tap.
The installation of this replace must conform with local codes or, in the absence of local codes, with the
National Fuel Gas Code, ANSI Z223.1.
The H Series Vent Free Gas Fireplace is shipped from the factory for use with natural gas ONLY.
Conversion to another fuel is NOT permitted.
This product must be installed by a licensed plumber or gastter when installed within the
Commonwealth of Massachusetts.
Note
2”x4” Opening for HVF-42-3S, HVF-60-3S,
HVF-72-3S Gas Connection