ELECTRIC INSTALLATION
16
Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation.
This appliance must be electrically grounded in accordance with local codes, or, in the absence of local
codes, with either the National Electrical Code ANSI/NFPA 70.
Electrical work should only be performed by a qualied, licensed electrician. Electric power must be o
when making connections or performing any service.
All wiring shall be in compliance with all local, city, and state codes.
Verify proper operation after servicing.
ELECTRICAL ASSEMBLY
The H Series replaces require the internal receptacle (supplied) to be wired to a 120V AC branch circuit
according to all applicable codes. The neutral, line and ground wires to the receptacle are available at the
lower left corner of the replace cabinet. This circuit must be wired such that the AC power to the H Series
replace may be turned o by an accessible single-pole switch. This circuit need not be dedicated to the H
Series replace unless required by local codes.
After the internal receptacle is connected and tested, the AC plug from the burner may be plugged in to it.
BATTERY BACKUP
The H Series replaces have a battery backup feature which, after 4 AA batteries are installed, powers the
system in the case of a commercial power loss. The battery case is in the left rear corner of the replace and
can be accessed by lifting o the hearth panel. Remove the battery case cover and insert four AA batteries as
shown in Figure 8.
Figure 8. Battery Case with Batteries
(shown with cover removed)