Owner`s manual

H Series Vent Free Gas Fireplace EuropeanHome.com
ROUGH INSTALLATION
15
ROUGH OPENING
Dimension HVF-42-3S HVF-60-3S HVF-72-3S
A (Width) 49” 62” 74”
B (Height) 34½” 34½” 34½”
C (Depth) 18½” 18½” 18½”
Table 4. Rough Opening Dimensions by Model
INSTALLING THE FIREPLACE
The H Series replaces must be placed on a sturdy and level surface. It can be placed on the oor or a raised
platform made ONLY of wood or non-combustible materials - do not place the replace on carpet or vinyl
tile.
1. Set the replace into position. Framing material can touch the standos at the sides and rear of the
cabinet but do not place anything between the framing and the standos.
2. Make sure the replace is both level and square.
3. Secure each of the three top standos (angle braces) into the wall framing. Use the fasteners required by
your local building code.
4. Compete the framing above the replace.
Figure 6. Rough Opening for HVF-42-3S, HVF-60-3S, HVF-72-3S
Three Standos MUST Be Se-
curely Attached To Framing
Figure 7. HVF-42-3S, HVF-60-3S, HVF-72-3S Standos
C
A
B