PRE-INSTALLATION PLANNING
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
When installing the H Series Fireplaces, the clearances shown in the table below must be observed. If the
required clearances are not maintained a re may result thereby causing property damage, personal injury
or loss of life.
When the replace is to be installed directly on carpeting, vinyl tile or combustible material other than wood
ooring, it must be installed on a metal or wood panel extending the full width and depth of the replace
cabinet.
When enclosing your replace, the use of non-combustible building materials
is required. Please read and understand the COMBUSTIBLE MATERIALS and
NON-COMBUSTIBLE MATERIALS sections on page 10.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
HVF-42-3S
HVF-60-3S
HVF-72-3S
Clearance to Top Cabinet Standos 0.0”
Clearance to Side Cabinet Standos 0.0”
Clearance to Cabinet Rear 0.0”
Clearance to Wood Floor 0.0”
Distance Between Cabinet Bottom and Enclosure Ceiling 34½”
Distance Between the Opening and a Side Wall in Front of the Fireplace 6.0”
Table 3. Minimum Clearances to Combustible Materials