(9) Abnormity and Solution 
Fault 
  Cause    Solution 
Light on, but motor 
does not work 
The leaf blocked  Get rid of the blocking 
The capacitor damaged  Replace capacitor 
The motor jammed bearing 
damaged 
Replace motor 
The internal with of motor off or 
a bad smell from the motor 
Replace motor 
Light does not work, 
motor does not work 
Beside the above mentioned, check the following: 
Light damaged  Replace lights 
Power cord looses  Connect the wires as per 
the electric diagram 
Oil leakage 
One way valve and the air 
ventilation entrance are not 
tightly sealed 
Take down the one way 
valve and seal with glue 
Leakage from the connection 
of U-shaped section and 
cover 
Take U-shaped section 
down and seal with soap 
or paint 
Shake of the body  The leaf damaged and causes 
shaking 
Replace the leaf 
The motor is not tightly 
hanged 
Lock the motor tightly 
The body is not tightly 
hanged 
Fixed the body tightly 
Insufficient suction  The distance between the 
body and the gas top too long 
Readjust the distance 
Too much ventilation from 
open doors or windows 
Choose a new place and 
resemble the machine 
The machine inclines  The fixing screw not tight 
enough 
Tighten the hanging 
screw and make it 
horizontal 
The hanging screw not tight 
enough 
Tighten the hanging 
screw and make it 
horizontal 