Installation guide

Logical Hardware Configuration
5-10 Fault Tolerant System Administration (R1004H) HP-UX version 11.00.03
Logical Cabinet Configuration
Cabinet components—such as CDC or ACU units, fans, and power supplies—do
not have true physical addresses. However, they are treated as pseudo devices and
given logical addresses for reporting purposes. The logical cabinet addressing
convention is as follows:
The first-level address, 12, is the logical cabinet nexus (CAB).
The second-level address identifies the specific cabinet number. For
Continuum Series 400/400-CO systems, this is always 0.
The third-level address identifies individual cabinet components. (The
number sequence is arbitrary.)
Figure 5-4 illustrates a logical cabinet configuration.
Figure 5-4. Logical Cabinet Configuration
The following sample ftsmaint ls output shows the logical hardware paths for
the field replaceable units for a Continuum Series 400 system with a Eurologic disk
enclosure.
Modelx H/W Path Description State Serial#PRev StatusFCode Fct
===========================================================================
d84006 14/0/0.15.0 EuroLogcESM-Lucent CLAIM 2.6 Online - 0
d84006 14/0/1.15.0 EuroLogcESM-Lucent CLAIM 2.6 Online - 0
e25800 12/0 ACU Cabinet 0 CLAIM - - Online - 0
PS Unit
14
CDC
0
Clock
33...
12/0/0 12/0/14 12/0/33
...
...
cabinet
cabinet
1
cabinet
0
2
Fan
6
CDC
0
Battery
28...
12/1/0 12/1/6 12/1/26
...
...
AC Ctlr
8
CDC
0
PC Unit
22...
12/2/0 12/2/8 12/2/22
...
...
GBUS
11
12
14
RECCBUS
0
1
LPKIO
CAB
LSM
LMERC
15
13
LNM
Main System Bus