5-36 Fault Tolerant System Administration (R1004H) HP-UX version 11.00.03
Fault Codes
The fault tolerant services return fault codes when certain events occur. The
ftsmaint ls command displays fault codes in the FCode (short format) or
Fault Code (long format) field. Table 5-9 lists and describes the fault codes.
Table 5-9. Fault Codes
Short
Format Long Format Explanation
2FLT Both ACUs Faulted Both ACUs are faulted.
ADROK Cabinet Address
Frozen
The cabinet address is frozen.
BLINK Cabinet Fault Light
Blinking
The cabinet fault light is blinking.
BPPS BP Power Supply
Faulted/Missing
The BP power supply is either
faulted or missing.
BRKOK Cabinet Circuit
Breaker(s) OK
The cabinet circuit breaker(s) are OK.
CABACU ACU Card Faulted The ACU card is faulted.
CABADR Cabinet Address
Not Frozen
The cabinet addresses are not frozen.
CABBFU Cabinet Battery Fuse
Unit Fault
The cabinet battery fuse unit fault
occurred.
CABBRK Cabinet Circuit
Breaker Tripped
A circuit breaker in the cabinet was
tripped.
CABCDC Cabinet Data
Collector Fault
The cabinet data collector faulted.
CABCEC Central Equipment
Cabinet Fault
A fault was recorded on the main
cabinet bus.