User manual

00102135.DOCX, Version 1.0
21/24
Controlling
After having addressed the LED SL-350 DMX Search Light, you may now start operating it via your lighting
controller.
Note:
After switching on, the device will automatically detect whether DMX 512 data is received or not. If the data
is received at the DMX-input, the red light above the display will blink. If there is no data received at the
DMX-input, the red light will not blink.
This situation can occur if:
- the XLR plug (cable with DMX signal from controller) is not connected with the input of the device.
- the controller is switched off or defective,
- the cable or connector is defective or the signal wires are swap in the input connector.
DMX protocol
Channel:
Value:
Function:
1
Colors
000 - 015 White
016 – 040 White + Red
041 – 063 Red
064 – 087 Red + Green
088 - 111 Green
112 - 136 Green + Yellow
137 - 159 Yellow
160 - 183 Yellow + Blue
184 - 207 Blue
208 - 231 Blue + Orange
232 - 255 Orange
2
Color temperature
000 – 063 8000K – 8500K
064 – 127 5600K
128 – 191 4500K
192 – 255 3200K
3
000 - 255 Iris
4
000 - 255 Dimmer with increasing brightness
5
Strobe
000 - 000 No function
001 - 127 Strobe-Effect with increasing speed
128 - 160 Pulse-Effect – fade out
161 - 191 Pulse-Effect – fade in
192 - 255 Random Effect
6
Reset
000 - 199 No function
200 - 239 Reset
240 - 255 No function
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection: