User manual

00056640.DOC, Version 1.0
20/24
The wires must not come into contact with each other, otherwise
the fixtures will not work at all, or will not work properly.
P
lease note, the starting address depends upon which controller is being used.
For the plug connection between controller and the device please use the enclosed adapter cable. For this
purpose, connect the DMX input plug of the device with the adapter cable. Fasten the locknuts on the
connectors. Then connect the 3-pin XLR-plugs of the adaper cable with the 3-pin XLR-connectors of the
controller.
To connect one fixture with another, connect the DMX output connector of the first fixture in the DMX chain
to the DMX input plug of the next fixture. Always connect one output with the input of the next fixture until all
fixtures are connected. If required, you can also use the 5 m extension cable (available accessory).
Occupation of the XLR-connection:
If you are using controllers with this occupation, you can connect the DMX-output of the controller directly
with the DMX-input of the first fixture in the DMX-chain. If you wish to connect DMX-controllers with other
XLR-outputs, you need to use adapter cables.
Building a serial DMX-chain:
Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next fixture. Always
connect one output with the input of the next fixture until all fixtures are connected.
Caution: At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120
resistor
between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.
Master/Slave-Operation
The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the EUROLITE LED PAR-64 RGBW 48 x 3 W you can find a DMX input plug and a
DMX output connector, which can be used for interconnecting several devices.
Choose the device which is to control the effects. Set the desired Master-mode on the master-device. This
device then works as master-device and controls all other slave-devices, which are to be connected to the
master-device via a balanced microphone lead. Set the DMX start address 001 on every slave-device and
the DMX mode on your master device. For example, if the master-device is set on the 6 channel mode
(CH6), all slave-devices have to be set on the 6 channel mode as well. Connect the DMX out connectors
with the DMX input plug of the next device.
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.