User manual

www.eurolite.de
28
DMX512 Operation
For operation with a controller with DMX512 protocol, the fog machine is equipped with 8 control channels.
To be able to operate the machine with a DMX controller, the DMX starting address must be set for the first
DMX channel. For this, press the button MENU so many times until Addris indicated in the display. Then
press ENTER to make your settings. Use the buttons and to set the address between 001 and 512.
Once again, press ENTER to confirm your settings. You may now start operating the machine via your DMX
controller. The section below describes all functions of the 8 control channels.
Channel 1 – Fog output
DMX value Function
000 – 009 off
010 – 255 on
Channel 2 – Brightness red LEDs
DMX value Function
000 – 009 off
010 – 255 Dimming from 1 – 100%
Channel 3 – Brightness green LEDs
DMX value Function
000 – 009 off
010 – 255 Dimming from 1 – 100%
Channel 4 – Brightness blue LEDs
DMX value Function
000 – 009 off
010 – 255 Dimming from 1 – 100%
Channel 5 – Brightness red, green and blue LEDs (color mixing)
DMX-Wert Funktion
000 – 009 off
010 – 255 Dimming from 1 – 100%
Channel 6 – Color change speed
DMX value Function
000 – 009 off
010 – 255
slow fast
Channel 7 – Strobe control
DMX value Function
000 – 009 off
010 – 255
slow fast
Channel 8 – Master dimmer
DMX value Function
000 – 009 off