User manual
27
•
EN
Fixture
Start address Fixture
Start address
1 1 5 81
2 21 6 101
3 41 7 121
4 61 8 141
Examples for start addresses of 4 KLS laser systems
Display Fixture type Mode
RGB Spot 5CH RGB spot lights with the DMX protocol:
1 Red, 2 Green, 3 Blue, 4 Dimmer, 5 Shutter/Stroboscope
5 ch mode
RGBA Spot 6CH RGBA spot lights with the DMX protocol:
1 Red, 2 Green, 3 Blue, 4 Amber, 5 Dimmer, 6 Shutter/
Stroboscope
6 ch mode
RGBW Spot 6CH RGBW spot lights with the DMX protocol:
1 Red, 2 Green, 3 Blue, 4 White, 5 Dimmer, 6
Shutter/Stroboscope
6 ch mode
RGBAW Spot 7 CH RGBAW spot lights with the DMX protocol:
1 Red, 2 Green, 3 Blue, 4 Amber, 5 White, 6 Dimmer, 7
Shutter/Stroboscope
7 ch mode
RGBAWUV Spot 6 CH RGBAWUV spot lights with the DMX protocol:
1 Red, 2 Green, 3 Blue, 4 Amber, 5 White, 6 UV
6 ch mode
RGBWAUV 6CH RGBWAUV spot lights with the DMX protocol:
1 Red, 2 Green, 3 Blue, 4 White, 5 Amber, 6 UV
6 ch mode
RGBUV Spot 6CH RGBUV spot lights with the DMX protocol:
1 Red, 2 Green, 3 Blue, 4 UV, 5 Dimmer, 6 Shutter
6 ch mode
KLS 30_and_50_20CH LED KLS-30 and LED KLS-50 20 ch mode
KLS-180_21CH LED KLS-180 21 ch mode
KLS-2500_23CH LED KLS-2500 23 ch mode
KLS-RGB_15CH LED KLS-200, LED KLS-400, LED KLS-401, LED KLS-800,
LED KLS-801, LED KLS-1001
15 ch mode
Laser_KLS-Spot_Derby_27ch
Laser_KLS_Effects_27CH
LED KLS Laser Bar FX
Caution! For this model, two fixtures need to be patched;
the first as „Laser_KLS-Spot_Derby_27ch“ and the second
as „Laser_KLS_Effects_27CH“. There must not be any gaps
in the DMX protocol, thus the start addresses must be
patched respectively, i.e. the start address of the second
fixture must follow directly after the start address of the first
fixture so that the display does not indicate an exclamation
mark.
27 ch mode
Laser_KLS-PRO-SPOT-Derby_28CH
Laser_KLS_PRO_Effects_28CH
LED KLS Laser Bar PRO FX
Caution! For this model, two fixtures need to be patched;
the first as „Laser_KLS-PRO-SPOT-Derby_28CH“ and the
second as „Laser_KLS__PRO_Effects_28CH“. There must
not be any gaps in the DMX protocol, thus the start
addresses must be patched respectively, i.e. the start
address of the second fixture must follow directly after the
start address of the first fixture so that the display does not
indicate an exclamation mark.
Fixture profiles available in the library