OPERATION
Install the device on a plane surface.
After you connected the device to the mains, the UV-tube lamp needs 3-4 minutes warm-up time until it
reaches full lighting output.
CLEANING AND MAINTENANCE
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
There are no serviceable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
Should you need any spare parts, please use genuine parts.
Should you have further questions, please contact your dealer.
TECHNICAL SPECIFICATIONS
Article: 51930322 60 cm 51930324 120 cm
Power supply: 230 V AC, 50 Hz ~ 230 V AC, 50 Hz ~
Power consumption: 8 W 18 W
Type of LED: SMD 5328, UV SMD 5328, UV
Number of LEDs: 144 288
Maximum ambient temperature. T
a
: 45° C 45° C
Maximum housing temperature T
C
(steady state): 60° C 60° C
Minimum distance from flammable surfaces: 0.5 m 0.5 m
Minimum distance to lighted object: 0.1 m 0.1 m
Dimensions (DxL excluding the length of the pins): 26 x 588 mm 26 x 1198 mm
Weight: 0.2 kg 0.35 kg
Please note: Every information is subject to change without prior notice. 12.02.2014 ©