3. Caution! The load has to be installed in a balanced way. The carrying capacity of the stand must never
b
e exceeded. The stand must be set up in a stable way. Make sure all fixation screws fit tight.
Rigging on a truss
The LED SCY-Bar can be fixed onto a truss using two theatre hooks.
Attach the theatre hooks on the SCY-Bar. Tighten the fixation screws
Suspend the theatre hooks in the truss and tighten the theatre hook screws.
Before rigging, make sure that the installation area can hold a minimum point load of 10 times the device's
weight.
Always install an appropriate safety bond.
You must only use safety bonds complying with DIN 56927, quick links complying with DIN 56927, shackles
complying with DIN EN 1677-1 and BGV C1 carbines. The safety bonds, quick links, shackles and the
carbines must be sufficiently dimensioned and used correctly in accordance with the latest industrial safety
regulations (e. g. BGV C1, BGI 810-3).
Please note: for overhead rigging in public or industrial areas, a series of safety instructions have to be
followed that this manual can only give in part. The operator must therefore inform himself on the current
safety instructions and consider them.
The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety
precautions!
A safety bond which already held the strain of a crash or which is defective must not be used again.
The maximum drop distance must never exceed 20 cm.
DANGER TO LIFE!
Please consider the EN 60598-2-17and the respective national standards during the installation!
The installation must only be carried out by an authorized dealer!
The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.
The installation must always be secured with an appropriate secondary safety element (e.g. steel rope). This
secondary safety attachment must be constructed in a way that no part of the installation can fall down if the