► Setting the Number of DMX Channels and the DMX Sarting address
For operation with a controller with DMX512 protocol, the light set is equipped with 27 control channels.
However, it can also be switched to a mode with 3, 5 or 9 channels if different functions are required. To be
able to operate the light set with a DMX controller, the DMX starting address must be set for the first DMX
channel. The starting address depends upon which DMX controller is being used. Please refer to the
controller’s documentation.
1
Press the button MENU so many times until dПH is indicated in the display.
2
Confirm with the ENTER button. Now the display indicates the menu item for the DMX start address
d***.
3
Confirm with the ENTER button, then use the buttons UP and DOWN to set the address.
4
Confirm with the ENTER button. The display indicates CH-03 (3 DMX channels), CH-05 (5 DMX
channels), CH-09 (9 DMX channels) or CH-27 (27 DMX channels).
5
Use the buttons UP and DOWN to select the desired number of DMX channels.
6
Confirm with the ENTER button. A dot will flash when DMX signals are being received. If no control
signals are available, the DMX address set will be flashing.
► Functions in DMX Mode
3-channel mode
Channel
Value Function
Blackout,
Automatic Mode and Sound
-
controlled Mode
1
000-009 Blackout
010-031 Automatic mode spots and derbies
032-065 Automatic mode laser
066-095 Automatic mode strobe LEDs
096-127 Automatic mode spots, derbies, laser and strobe LEDs
128-159 Sound control spots and derbies
160-191 Sound control laser
192-223 Sound control strobe LEDs
224-255 Sound control spots, derbies, laser and strobe LEDs
Automatic Mode
Spots
a
nd Derb
ie
s,
if channel 1 is set to a value between 010 and 031
2
000-009 AP01 Show program 1
010-019 AP02 Show program 2
020-029 AP03 Show program 3
030-039 AP04 Show program 4
040-049 AP05 Show program 5
050-059 AP06 Show program 6
060-069 AP07 Show program 7
070-079 AP08 Show program 8
080-089 AP09 Show program 9
090-099 AP10 Show program 10
100-109 AP11 Show program 11
110-119 AP12 Show program 12
120-129 AP13 Show program 13
130-139 AP14 Show program 14
140-149 AP15 Show program 15
150-159 AP16 Show program 16
160-169 AP17 Show program 17
170-255 AP18 Show program 18
Automatic
M
ode
Laser,
if channel 1 is set to a value between 032 and 065
2
000-039 AL01 Show program 1
040-079 AL02 Show program 2
080-119 AL03 Show program 3
120-139 AL04 Show program 4
140-159 AL05 Show program 5
160-255 AL06 Show program 6