INSTALLATION
This product is designed for overhead rigging only. Mount it to a wall or ceiling with the mounting bracket. If
necessary, it can also be fastened to a truss using appropriate clamps.
To align the unit, release the fixation screws at the mounting bracket, adjust the desired inclanation angle
and retighten the fixation screws. Make sure not to point the laser beams at highly reflective surfaces such
as mirror balls, windows and shiny objects. As a precaution, remove or cover up highly reflective objects in
order to avoid laser reflections
DANGER OF OVERHEATING!
The distance between the light output and the illuminated surface must be more than 0.1 m.
Always ensure sufficient ventilation. The ambient temperature must always be below 45 °C.
CAUTION!
The use of controls, adjustments, or performance of procedures other than what is specified
herein may result in hazardous radiation exposure.
DANGER LASER RADIATION!
Always set up and install the unit so that a minimum distance of 1 m is kept between the laser
light and the audience.
DANGER OF FIRE!
When installing the device, make sure there is no highly inflammable material within a
distance of min. 0.5 m.
Safety rope
Mounting clamp
Fixation screw
Mounting bracket