00081333.DOC, Version 1.0 12/13
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
During the operation, the lamp reaches temperatures of up to 80° C.
Procedure:
Step 2: If replacing a defective UV tube, remove the old UV tube from the socket.
Step 3: Insert the new UV tube into the lamp-socket and swivel it.
UV illuminants are hazardous waste which needs to be disposed of appropriately.
Please dispose of the unusable UV illuminants in accordance with the current legal regulations.
Attachment
Before attaching the device, make sure that the installation area can hold a minimum point load of 10 times
the device's weight.
The device must only be installed absolutely planar at a vibration-free, oscillation-free and fire-resistant
location. Make sure that the device is installed absolutely planar by using a water-level.
The device must be installed out of the reach of people.
The device must always be installed via all fixation holes. Do only use appropriate screws and make sure
that the screws are properly connected with the ground.
The durability of the installation depends very much on the material used at the installation area (building
material) such as wood, concrete, gas concrete, brick etc. This is why the fixing material must be chosen to
suit the wall material. Always ask a specialist for the correct plug/screw combination indicating the maximum
load and the building material.
Remove the mounting clips (2 versions) and screws included in delivery from the packaging and use
whichever clips are most suitable for the desired mounting area.
Procedure:
Step 1: Hold the clips onto the location where the device is to be installed.
Step 2: Mark the boreholes with a pen or a suitable tool.
Step 3: Drill the holes.
Step 4: Screw the suitable clips into the installation surface.
Step 5: Press the luminary carefully into the mounting clips until it clicks and the device is firmly fixed.
DANGER TO LIFE!
Before taking into operation for the first time, the installation has to be approved by an expert!
Connection with the mains
Connect the device to the mains with the enclosed power supply cable.
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.