User manual
00052605.DOC, Version 3.0
13/16
If this device will be operated in any way different to the one described in this manual, the product may suffer
d
amages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, lamp explosion, crash etc.
INSTALLATION
Installing/Replacing the lamp
DANGERTOLIFE!
Onlyinstallthelampwiththedeviceswitchedoff!
Unplugfrommainsbefore!
Thelamphastobereplacedwhenitisdamaged
ordeformedduetotheheat!
CAUTION!
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need one 6 V/30 W PAR-36 lamp.
During the operation, the lamp reaches temperatures of up to 130° C.
Procedure:
Step 1: Please remove the fixation ring by pressing it together.
Step 2: If replacing the lamp, remove the old lamp from the pinspot and loosen the wires.
Step 3: Loosen the screws on the new 6 V/30W PAR-36 lamp with an appropriate screwdriver.
Step 4: Connect the wires with the lamp using an appropriate screwdriver.
Step 5: Tighten the screws.
Step 6: Insert the lamp in the housing.
Step 7: Fix the lamp with the fixation ring.
Rigging
DANGEROFFIRE!
Wheninstallingthedevice,makesurethereisnohighly-inflammable
material(decorationarticles,etc.)withinadistanceofmin.0.5m.
The device can be installed on the ground or on the wall or ceiling.
Hanging installation