User manual
00026544.DOC, Version 2.1
16/37
If this device will be operated in any way different to the one described in this manual, the product may suffer
d
amages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, lamp explosion, crash etc.
OVERVIEW
(1) Mounting-bracket
(2) Hole for safety rope
(3) Tube
(4) Filter frame
(5) Silicone cable
(6) Mounting bracket screws
(7) Clip-to-hold clamps
INSTALLATION
Installing/Replacing the lamp
DANGERTOLIFE!
Onlyinstallthelampwiththedeviceswitchedoff!
Unplugfrommainsbefore!
Thelamphastobereplacedwhenitisdamaged
ordeformedduetotheheat!
CAUTION!
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need you need one PAR-56 pressed-glass lamp with up to max. 500 W.
Procedure:
Step 1: Remove the colour filter frame.
Step 2: Please remove the fixation ring by pressing it together.
Step 3: If replacing the lamp, remove the old lamp from the spot and remove the lamp socket.