User manual

00095814, Version 1.0
26/32
Default settings shaded.
Main menu Sub menu Display Function
SET ADDRESS
A001 ~ A508 DMX address setting
USER MODE
Channel Mode: 05 / 06 / 07 DMX channel mode
FUNCTION
Status
No DMX status
Close/Hold
Modes if no DMX
Fixture ID
Service PIN Password=XXX Passwort „050“
RDM PID
XXXXXX
Dimmer Curve
Linear
The increase in light intensity appears to be linear as
DMX value is increased
Square
Light intensity control is finer at low levels and coarser at
high levels
INV. Square
Light intensity control is coarser at low levels and finer at
high levels
S-Curve
Light intensity control is fine at low levels and high levels
and coarser at medium levels
Lamp Behavior
LED
Halogen
LCD. Set
Backlight 05M ~ 60M Display shutoff time
Key lock ON/OFF Key lock activation
DispFlash ON/OFF
Setting that the
device will flash when
there is no DMX
signal received
Load ON/OFF
Restore factory
settings
Temp. C/F
Celsius
Select temperature
designation °C or °F
Fahrenheit
INFORMATION
Time. Info
Current XXXX (h)
Power on running
time
Total time XXXX (h) Fixture running time
Last clear XXXX (h)
Individual fixture
running time
Timer PIN Password=„050“
Temp. Info XXX °C/°F Inside temperature
Model. Info LED THA-60PC Model name
Software version V 0.03 Software version
TEST
Panel. Ctrl. Dimmer = 000-255 Manual adjustment
Panel. Ctrl. Strobe = 000-255 Manual adjustment
Program
Static
R/G/B/RG/GB/RB/RGB/BLAC
F: 00 - 99
Manual adjustment
Change
SP: 01 – 99
F: 00 – 99
Manual adjustment
Fade
SP: 01 – 99
F: 00 – 99
Manual adjustment
Auto
SP: 01 – 99
F: 00 - 99
Manual adjustment
Sound Sense 00 - 31 Manual adjustment