Operation Manual

Before Use
8
Before Use
D. Filling Boiler with Water
WARNINGS:
Carefully read all instructions before removing Boiler Cap.
Always unplug appliance before lling the Boiler.
Follow these instructions to avoid overlling the
Boiler.
• Be sure appliance is unplugged, and has
cooled for at least 5 minutes before lling with
water.
Make sure Handle Assembly is in the upright
“Off” position.
Remove Boiler Cap by pressing
it down and turning it counterclockwise.
• Pour in a maximum of 0.6 l / 20 oz. water using
the provided measuring cup. Make sure that
water does not overow.
Replace Boiler Cap
by pressing it down and turning it clockwise.
If using cold water, heating time is about 3-5
minutes. If using warm water, heating time is
reduced.
*IMPORTANT*
Use tap water – distilled or demineralized water is recommended
if tap water is too hard.
DO NOT add detergents, perfumes, oils or
other chemical substances.
*IMPORTANT*
• Do not overll the Boiler as excess water will be ushed out of the
Boiler before dry steam will emit.
• If re-lling the Boiler while Steamer has been in use, be sure to allow
Steamer to cool for at least 5 minutes and loosen Boiler Cap slowly
to allow any excess steam to escape before completely removing
Cap. (See step 2D, “Relling Boiler During Use” for detailed instruc-
tions.)