Hardware manual

EUROCOM-17-5xx 2 Installation
Hardware Manual 45
2.3.9.2 Hardware
Configuration
(S902)
The lower switch (S902) defines the configuration source and the
operation mode. For switch position 0, 1, RMon enters an interactive
mode. If switch S902 is in position 8 to F, the program located in the user
EPROM is called.
S901 and S902 have no direct influence. A changed position becomes only
effective after the next reset (i.e. the software reads the switches and
programs the appropriate registers).
2.3.9.3 System
Controller
Switch (S3)
Table25: Switch S3 (System Controller Switch)
Table24: Hex Switch S902 (Hardware Configuration)
Hex Switch
S902
Function
0 Hardware configuration from basic EPROM
1 Hardware configuration from SRAM
2 Reserved for ELTEC
3 RMon interactive mode on serial port
4 RMon interactive mode on dual-ported RAM
(local address $C000)
5 - 7 Reserved for ELTEC
8 - F Hardware configuration from SRAM and start program in user EPROM.
Hex Switch S3 Function
left System controller disabled
right 'SC' System controller enabled
i