Installation guide
1 Getting Started OS-9 V2.4 on EUROCOM-17
2 Software Manual
If you want to use a VGA monitor and MF-2 keyboard, set hex switch S2
to '0'.
Connect the floppy drive(s) and harddisk(s) according to the description in
the hardware manual and jumper them as mentioned in Section4.2 ‘Fixed
Device Parameters’ of this manual.
Now switch on the terminal and the EUROCOM-17. The LED display
now indicates 'F', and you should get the power-on message of the RMon
monitor from the terminal.
The monitor program on EUROCOM-17 has a SCSI command (check
SCSI bus). This command can be used to check connected devices on the
SCSI bus. It checks SCSI IDs 0 till 6 and on each ID logical unit number
(LUN) 0 till 3. For ever ready device a '+' is issued.
At this point boot OS-9/68K (see Section2.1 ‘Booting from Floppy
Disk’).