Specifications
-3.6-
SYS 1 SYS 2 SYS 3 DCU OK Code Name
GREEN GREEN YELLOW RED 214 PRC_STATUS_RUNNING_ON_BATTERY
SYS 1 SYS 2 SYS 3 DCU OK Code Name
GREEN YELLOW YELLOW RED 246 PRC_STATUS_PDU_NO_CONNECTION
Description:
Action:
SYS 1 SYS 2 SYS 3 DCU OK Code Name
OFF GREEN GREEN RED 082 PRC_STATUS_RAP_MISSING
SYS 1 SYS 2 SYS 3 DCU OK Code Name
YELLOW OFF YELLOW RED 206 PRC_RECORDING_STOPPED_INDICATION
SYS 1 SYS 2 SYS 3 DCU OK Code Name
RED RED GREEN RED 106 PRC_STATUS_SYSTEM_STOPPED
SYS 1 SYS 2 SYS 3 DCU OK Code Name
RED YELLOW RED RED 238 PRC_SYSTEM_DRIVE_FAILURE
SYS 1 SYS 2 SYS 3 DCU OK Code Name
RED RED YELLOW RED 234 PRC_UTC_TIMEOUT
SYS 1 SYS 2 SYS 3 DCU OK Code Name
YELLOW GREEN YELLOW RED 254 PRC_SELFTEST_FAILED
SYS 1 SYS 2 SYS 3 DCU OK Code Name
OFF RED YELLOW RED 226 PRC_NUM_FLASH_DRU_ERROR
Description:
System failed to find correct number of Flash drives in DRU.
Action:
Check communication with DRU.
Description:
System failed the SELFTEST.
Action:
Connect via webbrowser or VGA screen to see reason for failure.
Description:
System has not received UTC information within 2 minutes after system start up.
Action:
Check that a valid UTC source is connected to the serial port defined as UTC source.
Description:
System did not find valid System drive(DRU).
Action:
Check that a valid DRU is connected(Validated flashdrives installed).
Description:
SYSTEM_STOP - request has been completed (system has stopped collecting data).
Action:
Turn OFF POWER to power down, or recycle POWER to restart
Description:
VR-5000 has stopped recording. System has been running on BATTERY only for more
than 2 hours, or index has been cleared and system has not been rebooted.
Action:
Reconnect AC or DC. The system will start recording after 30 sec.
The cable between the PDU and DPU is not connected.
Reconnect the cable between the PDU and DPU.
Description:
Remote alarm panel is missing. Connection to R.A.P. is lost.
A
ction:
Check Cable to R.A.P.
Reconnect R.A.P.
Description:
Both AC and DC power are down. Audible alarms will only be generated for max 2 min.
Action:
Reconnect AC or DC power.