Specifications

-3.3-
SYS 1 SYS 2 SYS 3 DCU OK Code Name
YELLOW YELLOW YELLOW GREEN
253
PRC_STATUS_OK_INDICATION
SYS 1 SYS 2 SYS 3 DCU OK Code Name
YELLOW YELLOW YELLOW YELLOW
SYS 1 SYS 2 SYS 3 DCU OK Code Name
REDREDREDRED
170
PRC_STATUS_FATAL_FAILURE_INDICATION
SYS 1 SYS 2 SYS 3 DCU OK Code Name
RED OFF OFF RED
010
PRC_STATUS_DRU_FAILURE_INDICATION
SYS 1 SYS 2 SYS 3 DCU OK Code Name
YELLOW OFF OFF RED
014
PRC_STATUS_BACKUP_DEVICE_FAILURE
SYS 1 SYS 2 SYS 3 DCU OK Code Name
OFF RED OFF RED
034
PRC_STATUS_STORAGE_FAILURE_INDICATION
SYS 1 SYS 2 SYS 3 DCU OK Code Name
YELLOW RED OFF RED
046
PRC_STATUS_DRU_INDEX_ERROR
SYS 1 SYS 2 SYS 3 DCU OK Code Name
GREEN GREEN OFF RED
022
PRC_STATUS_STORAGE_DRU_CONNECTION_TIMEOUT
SYS 1 SYS 2 SYS 3 DCU OK Code Name
YELLOW YELLOW OFF RED
062
PRC_STATUS_STORAGE_LAST_BUFFER_NOT_SAVED
V
R-5000 error codes (3.0)
Description:
System is running normally with no errors pending.
Action:
None.
Description:
VR-5000 has been turned on. Wait for 2 minutes to watch LEDs start 'roll-flash'.
Action:
If LEDs do not flash after 2-3 minutes, system is unable to start normally. Call for
service.
Description:
FATAL SYSTEM ERROR
Action:
Request service.
Description:
System is experiencing trouble communicating with the DRU.
Action:
Trouble-shoot connection from VR-5000 to the DRU(cable, repeaters and possible
IEEE1394/Firewire - board in the PDU.)
Description:
Backup device is either faulty or not set up correctly.
Action:
Replace or reconfigure backup device.
Description:
Problem with storing data on storage devices.
Action:
Investigate LOG and repair/replace.
Description:
Problem with INDEX in DRU.
Action:
Investigate LOG and clear INDEX.
Description:
DRU has been disconnected more than 90 seconds.
Action:
Connect DRU again or investigate LOG and repair/replace.
Description:
Storage problem with DRU/BACKUP.
Action:
Investigate LOG(if possible) or contact supplier for repair.