Make the following AES Sync connections:
Attach the provided XLR-to-Lemo cable from one of the AES Sync Out con-
nectors on the SH612 to the AES Sync In connector on the FC631 card of the
first DF64.
Attach the provided Lemo-to-Lemo cable from one of the AES Sync Out ports
on the first DF64 to the FC631 card of the second DF64 (if present). Daisy
chain this connection to additional DF64s.
Attach the provided yellow XLR cable from one of the AES Sync Out connectors
on the SH612 to the AES Sync In of the AM713 or DM714. Daisy chain this
connection to other AM713(s), DM714(s), MD704, or other digital devices
with an AES Sync input.
Attach the provided yellow XLR cable from one of the AES Sync Out connectors
on the SH612 to the AES Sync In of the MA703 or MD704. Daisy chain this
connection to other MA703(s) or MD704(s).
Attach the provided yellow XLR cable from one of the AES Sync Out connectors
on the SH612 to the AES Sync In of other devices with AES Sync inputs
whose sample clocks must be locked to System 5 (i.e., the R-1).
The Word Clock output of the SH612 can also be used to sync to an external
device or group of devices using daisy chain cabling.
NOTE: The AES Thru port on the Euphonix converters is always active. If daisy chained de-
vices are powered off, downstream devices will lose sync.