User guide

Euphonix SH612 Studio Hub User Guide Getting Started
6
Synchronization signals are distributed via four AES Sync (AES/EBU), Word Clock,
video, or MTC outputs to System 5 or R-1 components. The SH612 can generate or
lock to Time code, or convert between different formats. All standard time code rates
are supported:
Film: 24 fps
PAL/SECAM: 25 fps
Color NTSC: 29.97 (drop and non-drop)
black and white video rate
MIDI sequencers: 30 fps (drop and non-drop)
The SH612 routes digital audio via 12 MADI In and 12 MADI Out ports, each with the
capacity to receive or transmit up to 56 channels (up to 24-bit, 48 kHz). For sample
rates exceeding 50 kHz, each MADI channel can carry only 28 digital audio channels.
1.1.2 Power On Sequence
Attach the provided IEC-compatible power cable to the IEC inlet. Connect the other
end to a wall outlet with appropriate plug adapter if necessary. The SH612 power sup-
ply automatically adjusts to any voltage in the range 110–240 V.
We recommend powering up the SH612 before the digital devices to which it is con-
nected. The SH612 conducts a brief self-test routine upon power-up and displays the
firmware revision number. When the Main Menu is displayed, power up the attached
converters.
NOTE: Please refer to the power up routine for System 5 before attempting to power the
DF64 Digital Frames and the Pilot Computers.
1.2 MADI Connections for the R-1
These are the standard MADI connections for the R-1:
MADI Ports 1–4 are for converter or I/O devices
MADI Port 7 is for AudioDeck 1
MADI Port 8 is for AudioDeck 2
MADI Port 9 is for AudioDeck 3
MADI Port 10 is for AudioDeck 4
MADI Ports 5, 6, 11, and 12 are for additional MADI devices that require a
custom route to be used with the R-1 (see Section 3.1.5 - MADI Routing Menu).