User guide
Euphonix SH612 Studio Hub User Guide Front and Rear Panel Interface
17
Control (9-pin DIN): Use this RS422 port for software control of the SH612 from
System 5 (but not for the R-1).
IEEE 1394 ports (3): Use this IEEE 1394 high-speed communication protocol for soft-
ware control of the SH612 from the R-1 (but not for System 5).
NOTE: The SH612 can now be controlled by either its serial 9-pin Control port or by its IEEE-
1394 port. The unit may appear to be disabled if the port selected for software control
does not match the actual port currently connected. If software control is not working
in System 5 version 2 or R-1 version 3 (and later versions of each), follow these steps:
1. Start the SH612 and press Select once to enter the Main Menu.
If the SH612 does not display its Main Menu, press the Escape key several
times until the status display is shown, then press Select again.
2. Turn the SpinKnob to highlight Utility Menu and press Select.
3. Turn the SpinKnob to highlight Control Port and press Select.
For System 5, turn the SpinKnob to highlight RS422 and press Select.
For an R-1, turn the SpinKnob to highlight (IEEE) 1394 and press Select.
4. Press Escape twice to show status again.
5. Reboot the SH612 to implement the control port change.
Serial MC RS422 (9-pin DIN): Input port for Machine Control signals. Not used in
System 5.
MTC/MMC In (5-pin DIN): Input port for MIDI Time Code or MIDI Machine Control
signals.
MTC/MMC Out (5-pin DIN): Output port for MIDI Time Code or MIDI Machine
Control signals.
MTC/MMC Thru (5-pin DIN): Duplicates the signal applied to the MTC/MMC In port.
LTC In (1/4" phono and XLR): Input SMPTE LTC.
LTC Out (1/4" phono and XLR): Generates SMPTE LTC at the time code frame rate
set by the System 5 software.
Power Connector (IEC): Accepts standard IEC power cord (provided). An autoranging