Euphonix MADI Converters Manual AM713 Analog to MADI, MA703 MADI to Analog DM714 Digital to MADI, MD704 MADI to Digital Document Revision: 2.1 Release Date: December, 2003 Part Number: 840-08416-02 Euphonix Inc. 220 Portage Ave. Palo Alto, California 94306 Phone: 650-855-0400 Fax: 650-855-0410 Web: http://www.euphonix.com e-mail: info@euphonix.
In the interest of continued product development, Euphonix Inc. reserves the right to make improvements in this manual and the products it describes at any time, without notice or obligation. System 5, S5, Max Air, PatchNet, eMix, EuCon, R-1, Audio Deck, Studio Hub are trademarks of Euphonix, Inc. ©2002 Euphonix, Inc. All rights reserved worldwide.
IMPORTANT SAFETY INSTRUCTIONS The lighting flash with arrowhead symbol within an equilateral triangle, is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electrical shock to persons. The exclamation point within an equilateral triangle, is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product.
13) Unplug this apparatus during lightning storms or when unused for long periods of time. 14) Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Euphonix MADI Converters Operation Manual Table of Contents List of Figures ....................................................................................................................... vi Chapter 1: Introduction ...................................................................................................7 1.1 AM713/MA703 .........................................................................................7 1.2 DM714/MD704 .............................................................
Euphonix MADI Converters Operation Manual List of Figures 2-1 AM713 Front Panel ..........................................................................................................12 2-2 AM713 Rear Panel ............................................................................................................14 2-3 MA703 Rear Panel ............................................................................................................16 3-1 DM714 Front Panel .............................
Euphonix MADI Converters Operation Manual Chapter 1: Introduction 1.1 AM713/MA703 The AM713 and MA703 converters provide MADI conversion to interface to/from analog equipment such as consoles, tape decks, microphone preamplifiers and other analog devices. Both converters are two rack spaces high and are housed in a stainless steel chassis with machined, heavy aluminum front panels. The AM713 converts incoming analog signals to 24-bit MADI digital signals that capture the input’s complete dynamic range.
Euphonix MADI Converters Operation Manual 1.3 Introduction Power On Sequence We recommend powering up the converters only after verifying the presence of a valid sync signal. After powering up the converters, the meter LEDs flash briefly and the Sample Rate and Sample Rate Source LEDs blink as the converter senses the incoming Sample Rate source and Sample Rate.
Euphonix MADI Converters Operation Manual Introduction Power Cord Requirements The converters are supplied with North American IEC power cords. If this cord is changed to allow a different plug configuration, it is the responsibility of the user to select an approved power cord with proper construction material, current capacity, flexibility, and strength characteristics. Cooling We strongly recommend providing adequate ventilation to the converters, particularly when installed in a rack.
Euphonix MADI Converters Operation Manual Introduction 10
Euphonix MADI Converters Operation Manual Chapter 2: AM713 and MA703 Converters 2.1 Features Professional grade audio conversion is accomplished utilizing 128 times over-sampled noise-shaped delta-sigma techniques. The analog to digital conversion employs a multi-bit modular architecture while the digital to analog conversion employs a single-bit modulator architecture. Low-jitter reference clocks are provided utilizing digital PLL techniques with VCXO and VCO oscillators.
Euphonix MADI Converters Operation Manual 2.3 AM713 and MA703 Converters AM713/MA703 Front Panel This section discusses both front panels and notes their few differences. Figure 2-1 AM713 Front Panel Signal Strength LEDs: Each of the 28 channels has a four-segment LED that represents the following signal levels: -42 dB, -18 dB, -6 dB (green), -0.05 dB (red). Trim Pots Access: Three trim pots adjust the maximum analog level of channels 1–8, 9–16, and 17–24 in 2-dB steps between +12 and +26 dBu.
Euphonix MADI Converters Operation Manual AM713 and MA703 Converters Manual Selection Buttons: The button below each Sample Rate LED row manually selects the sample rate. The AM713 also allows manual selection of the Sample Rate Source. Power Switch: On/Off switch. NOTE: There are no user-serviceable parts in the converters.
Euphonix MADI Converters Operation Manual 2.4 AM713 and MA703 Converters AM713 Rear Panel AM713 DIGITAL INPUTS ANALOG INPUTS MADI OUT Figure 2-2 AM713 Rear Panel Input Voltage Selector: This red switch allows the unit to operate in either 110/115 VAC or 220/230/240 VAC environments. A fuse must also be changed for 220/230/240 VAC operation (see page 8). Units are shipped set and fused for 110/115 VAC. Power Connector (IEC) and Fuse Tray: The IEC power connector accepts standard IEC power cords.
Euphonix MADI Converters Operation Manual AM713 and MA703 Converters MADI Out (BNC): Outputs the digital audio signal. • 1–24: Analog inputs • 25–26: Aux analog inputs • 27–28: Aux digital inputs NOTE: 28 channels are always transmitted; dual channels are not used.
Euphonix MADI Converters Operation Manual 2.5 AM713 and MA703 Converters MA703 Rear Panel MA703 MADI IN DIGITAL OUTPUTS ANALOG OUTPUTS Figure 2-3 MA703 Rear Panel Input Voltage Selector: This red switch sets the unit to either 110/115 VAC or 220/ 230/240 VAC environments. A fuse must also be changed for 220/230/240 VAC operation (see page 8). Units are shipped set and fused for 110/115 VAC. Power Connector (IEC) and Fuse Tray: The IEC power connector accepts standard IEC power cords.
Euphonix MADI Converters Operation Manual AM713 and MA703 Converters MADI In (BNC): Digital audio signal input.
Euphonix MADI Converters Operation Manual 2.6 Synchronization 2.6.1 AM713 AM713 and MA703 Converters The AM713’s Sample Rate is set externally by one of two source signals or internally by crystals and associated circuitry. The Sample Rate Source is determined automatically by the presence of signals when the AM713 is powered on. The order in which external signals are tested for presence is: AES, Word, Internal. The detected signal immediately becomes the source for the AM713’s sample rate clock.
Euphonix MADI Converters Operation Manual 2.7 AM713 and MA703 Converters Specifications AM713 Performance Specifications Sync Sources AES, word clock, internal Sync Outputs AES thru and word clock out Sync Detection Auto or switched Internal Sample Rate 44.1, 48, 88.2, 96 kHz ±50 ppm Lock range fine mode custom mode Audio Inputs ±300 ppm ±12% varispeed of 44.
MA703 Performance Specifications Sync Sources AES, word clock, MADI Sync Outputs AES thru and word clock out Sync Detection Auto or switched Internal Sample Rate 44.1, 48, 88.2, 96 kHz ±50 ppm Lock range fine mode custom mode ±300 ppm ±12% varispeed of 44.1 and 48 kHz Above 50 kHz, varispeed can adjust the nominal sample rate by -12 to +5% MADI Input BNC 75 Ω 44.1/48 kHz: 56 channels 88.2/96 kHz: 28 channels. Outputs mapped to channels 1–24, A1/2 to 25/26, D1/2 to 27/28.
Euphonix MADI Converters Operation Manual AM713 and MA703 Converters AM713/MA703 Technical Specifications Power Requirements 110/115 VAC or 220/230/240 VAC; 50 or 60 Hz Power Consumption 50 W Temperature of Operation 5–35°C Dimensions Height: 3.5 in; Width: 19 in; Depth: 18.
Euphonix MADI Converters Operation Manual AM713 and MA703 Converters 22
Euphonix MADI Converters Operation Manual Chapter 3: DM714 and MD704 Converters 3.1 Features AES/EBU and Word Clock external sync inputs on both units provide synchronization to digital systems. Sample Rate Source and Sample Rate are automatically sensed by both units. Supported sample rates include 44.1, 48, 88.2, and 96 kHz. In addition, pull-up and pull-down rates for the standard sample rates, as well as custom sample rates are available.
Euphonix MADI Converters Operation Manual 3.3 DM714 and MD704 Converters DM 714/MD704 Front Panel This section discusses both front panels and notes their few differences. Figure 3-1 DM714 Front Panel Signal Strength LEDs: Each of the 28 channels has a four-segment LED that represents the following signal levels: -42 dB, -18 dB, -6 dB (green), -.05 dB (red). Trim Pot: A trim pot adjusts the analog output level of channels A1 and A2 between +12 and +26 dBu in 2-dB steps.
Euphonix MADI Converters Operation Manual DM714 and MD704 Converters • AES: Sample Rate locked to AES Input. • Word: Sample Rate locked to Word Clock Input. • Internal (DM714 only): Sample Rate locked to its own internal crystal. • MADI (MD704 only): Sample Rate locked to MADI. • Auto: Sample Rate Source has been auto-sensed. These LEDs appear in the same order in which signals are tested for presence. This detection procedure occurs when the converters are powered on.
Euphonix MADI Converters Operation Manual 3.4 DM714 and MD704 Converters DM714 Rear Panel DM714 AES/EBU INPUTS DIGITAL INPUTS MADI OUT S/PDIF D1/D2 AES D1/D2 A2 A1 7/8 5/6 3/4 1/ 2 PARALLEL AES/EBU INPUTS 1-8 15/ 16 13/ 14 11/ 12 9/ 10 9-16 IN WORD 23/ 24 OUT SYNC 21/ 22 19/ 20 17/ 18 17-24 AES Figure 3-2 DM714 Rear Panel Input Voltage Selector: This red switch allows the unit to operate in either 110/ 115 VAC or 220/230/240 VAC environments.
Euphonix MADI Converters Operation Manual DM714 and MD704 Converters Word Out (BNC): Outputs a Word clock signal synchronized to the Sample Rate Source. In the presence of an external Word clock input, this connector provides a regenerated version of that input signal. Without an external sample rate source, this connector outputs the internally generated clock signal. MADI Out (BNC): Outputs the digital audio signal.
Euphonix MADI Converters Operation Manual 3.
Euphonix MADI Converters Operation Manual DM714 and MD704 Converters MADI In (BNC): Digital audio signal input. • 1–24: main digital outputs • 25–26: aux analog outputs • 27–28: aux digital outputs Bit-Depth Reduction: Sets the resolution to 16, 20, or 24 bits for the main AES/EBU channels.
Euphonix MADI Converters Operation Manual 3.6 Synchronization 3.6.1 DM714 DM714 and MD704 Converters The DM714’s Sample Rate is set externally by one of two source signals or internally by crystals and associated circuitry. The Sample Rate Source is determined automatically by the presence of signals when the DM714 is powered on. The order in which external signals are tested for presence is: AES, Word, Internal. The detected signal immediately becomes the source for the DM714’s sample rate clock.
Euphonix MADI Converters Operation Manual 3.7 DM714 and MD704 Converters Specifications DM714 Performance Specifications Sync Sources AES, word clock, internal Sync Outputs AES thru and word clock out Sync Detection Auto or switched Internal Sample Rate 44.1, 48, 88.2, 96 kHz ±50 ppm Lock range fine mode custom mode Audio Inputs ±300 ppm ±12% varispeed of 44.
Euphonix MADI Converters Operation Manual DM714 and MD704 Converters MD704 Performance Specifications Sync Sources AES, word clock, internal Sync Outputs AES thru and word clock out Sync Detection Auto or switched Internal Sample Rate 44.1, 48, 88.2, 96 kHz ±50 ppm Lock range fine mode custom mode ±300 ppm ±12% varispeed of 44.
Euphonix MADI Converters Operation Manual DM714 and MD704 Converters AM713/MA703 Technical Specifications Power Requirements 110/115 VAC or 220/230/240 VAC; 50 or 60 Hz Power Consumption 25 W Temperature of Operation 5–35°C Dimensions Height: 3.5 in; Width: 19 in; Depth: 18.
Euphonix MADI Converters Operation Manual 3.
Euphonix MADI Converters Operation Manual 3.
Euphonix MADI Converters Operation Manual DM714 and MD704 Converters 36